All downloads for AMA 310 Basic and AMA 310 Complete D3.0.
Printout with Logo
Please find an example for a userdefined logo. The printout of an AMA 310 can be supplemented by adding this logo.
Using a drawing program you can change the file »Demologo.bmp« as requested. The text can be deleted in most cases with a tool called »Eraser«. Afterwards there is the possibility to add new text or an icon, for example.
The file type (file extension ».bmp«) and the horizontal resolution of 384 pixel has to be maintained. The height of the logo must not exceed the maximum of 384 pixel.
Software update AMA 310
Download Version (Vxx_21i) EN as zip file.
We strongly recommend to use the supplied mini USB stick for the update!
You can load a new firmware release onto your instrument at any time. Please pay attention to the users manual!
If you have any technical problems, feel free to contact us by e-mail – you will find the contact details here.
Softwarehistory
AMA 310, AMA 310/UMS, HE 310 V .. 21
Option DOCSIS 3.1-Analyzer with DOCSIS 3.1 cablemodem supported
Upstream-Monitoring-System UMS: Enhancement up to 20 field devices
SNMP-enhancement (MIB-Version V 2.8)
AMA 310, AMA 310/UMS, HE 310 V .. 20
Option DOCSIS 3.1 Downstream (FPGA-Demodulator) supported
Primary/Secondary-Detection DOCSIS-Downstream for ScQAM and OFDM
SNMP-enhancement (MIB-Version V 2.7)
Datalogger: automatic increment of filename
User-defined channel table supports DOCSIS 3.1-OFDM Downstream D-Channels
Bug Date/Time attachement of created files fixed
AMA 310, AMA 310/UMS, HE 310 V .. 19
Improvements at UNICABLE and JESS
DataLogger measurement type »level only«
Additional D channels in channel table
DVB-S2: Improvements for PLS (Physical Layer Scrambling) and MIS (Multible Input Stream)
Option DRA
Remote access improved with SNMPv3 and FTP
AMA 310 V .. 18
Transport stream data rate measurement at DVB-S/S2/C/T/T2/DTMB and ASI input
File names serially numbered at hardcopy to bmp-file
Display of program name at analog TV extracted from videotext header
Improvements at UNICABLE and JESS
SNMP-enhancement
AMA 310 V .. 17
Option HEVC und AVS+ is supported
DVB-S2: 16/32 APSK extension
DVB-T2: L1 Parameter extended, PLP Selection possible
Constellation diagram with DVB-T2 possible
DAB: Bit Error Rate measurement after Viterbi at DAB+ services
TV: Frequency extended to 1,214 MHz
DTMB: Automatic search function SingleCarrier/MultiCarrier implemented
JESS: Extension to 32 UB slots
AMA 310 V .. 16
Option 1.2 GHz is supported
Additonal Span 867 MHz in TV Analyzer for devices running up to 1,050/1,200 MHz
AMA 310 V .. 14
Option DTMB is supported
Display and printout of an LCN list possible
AMA 310 V .. 13
Speed-Test in the DOCSIS-3.0 analyzer possible
AMA 310 V .. 12
Option Optic is supported
Headend mode (depending up on the hardware-stand) = Return path measurement with VAROS 107 is possible as a transmitter
Hum measurement with DVB-C, DOCSIS, PRBS also in percent
AMA 310 V .. 11
Support the DOCSIS 3.0 option
Reception/Evaluation of QAM-PRBS in conjunction with VAROS 107 (upstream generator) activated (depending up on the hardware-stand)
AMA 310 V .. 10
Option DVB-T2 is supported
Hardcopy »LCD« can be attached with Hardcopy »Graphics«
AMA 310 V .. 09
New Unicable standard JESS programming of SAT outlets (hardware dependent)
Automatic tracing of SCR-ADRs in UNICABLE mode
Monitoring program up to one week
Modified handling of channel table with AMA.remote
AMA 310 V .. 08
Four user-defined UNICABLE databases
Tilt measurement in BK spectrum
AFC can be switched off in DVB-S/S2 (resolution 0.1 MHz)
NIT print from ASI is possible
LCN is readable with NIT (depending up on the hardware-stand)
Dynamic PMT can be activated (depending up on the hardware-stand)
AMA 310 V .. 07
The downstream capacity can be documented with DOCSIS (as well as in the data grabber)
Higher flexibility with the EMI measurement
Up to 200 measurements are recordable
Measurementdepth from the Bit error measurement EURO DOCSIS and QAM up to e-9 possible
Upstream frequency for ranging is selectable
AMA 310 V .. 06
Level measurement in dBmV and dBm
Reception settings for DVB-C and DOCSIS are adjustable
Six user defined headers by print-out
MAX-Hold-Function in all analyzer ranges
Subtitles by DVB (depending up on the hardware-stand)
Warning by software downgrade
AMA 310 V .. 05
Electro magnetic interference measurement possible (optional)
DOCSIS 2.0 analyzer with Ping-Test (optional)
A logo and 3 user-defined lines can be integrated by print out
Channel table B/G: S4 adjusted.
User-defined channel table can be processed and charged with the AMA.remote
AMA 310 V .. 04
Highpass Filter for the S2/3 measurement is switchable
Data from the built in Flash Memory can easily be exported on to the USB-Stick
Phase jitter measurement is possible with level information in DVB-C and DOCSIS (but for this function the instrument must come into the factory)
AMA 310 V .. 03
SNMP-connection optional is possible
Graphic Measurement Data Recording (DataGrabber)
Automatic input memory function
Print-out of singular Measurements
Real »Made in Germany«
Find out why we are who we are …Your KWS newsletter keeps you cutting-edge with all of our devices, newest software updates and much more: SUBSCRIBE NOW.